How to test satellite components using a thermal vacuum chamber?

Source:LINPIN Time:2025-06-10 Category:Industry News

In order to verify the ability of satellite components to withstand vacuum thermal environments, a thermal vacuum chamber is used for testing. The purpose is to validate the rationality of the design and identify defects in the components, materials, and manufacturing processes. Here is how to conduct the test using a thermal vacuum chamber:

thermal vacuum chamber
Satellite Component Thermal Vacuum Test Method:
Test Equipment:
Thermal vacuum chamber
Test Sample:
Satellite component
Test Procedure:
Start the test equipment and activate the vacuum pumping system to reduce the pressure inside the vacuum chamber from normal ambient pressure to the required test pressure value.
Cool down. Activate the cooling and temperature control system to lower the component temperature from normal ambient temperature at the temperature change rate specified in the dedicated test technical document. When the temperature displayed by the control thermocouple sensor reaches and stabilizes at the required lowest test temperature, maintain this temperature for the specified duration, conduct performance tests on the component, and record the results. Then, end the low-temperature holding state.
Heat up. Activate the heating and temperature control system to raise the component temperature from the low-temperature test temperature at the temperature change rate specified in the dedicated test technical document. When the temperature displayed by the control thermocouple sensor reaches and stabilizes at the required highest test temperature, maintain this temperature for the specified duration, conduct performance tests on the component, and record the results. Then, end the high-temperature holding state.
Cool down again. Lower the component temperature from the high-temperature test temperature at the temperature change rate specified in the dedicated test technical document until it reaches normal ambient temperature, completing one full test temperature cycle.
For components requiring multiple temperature cycles, repeat steps 2 to 4 until the specified number of temperature cycles is reached.
After the component and the entire thermal vacuum simulation chamber have returned to normal temperature, stop the vacuum pumping. If necessary, conduct a performance test on the component.
Before repressurizing the vacuum chamber, during the process of raising the temperature of the heat sink to room temperature at low temperature, the external surface temperature of the component should be at least 10℃ higher than the temperature of the heat sink.
Use the repressurization system of the equipment to inject dry, clean, and non-polluted gas into the space simulation chamber to repressurize it, and then remove the component.

News Recommendation
When a temperature cycling test chamber malfunctions, how should you troubleshoot it? Have you identified the correct diagnostic approach? Mastering the right methods can help quickly locate the issue and restore functionality more efficiently.
Door locks, headlights, electrical dust covers, instrument panels, and other components can be tested for dust resistance using a sand and dust test chamber.
A salt spray test chamber is an accelerated corrosion environmental testing device. The primary causes of metal corrosion include oxygen, salt particles, pollutants in the air, as well as changes in temperature and humidity.
Many people still have questions about rain test chambers. Today, we’ll address a few of them.
Intelligent control is crucial for rain test chambers.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn
主站蜘蛛池模板: 北安市| 云南省| 长白| 彭泽县| 兰坪| 永福县| 宣汉县| 韩城市| 饶平县| 东山县| 安平县| 贞丰县| 赣榆县| 贡嘎县| 灯塔市| 东光县| 邵阳市| 霸州市| 巴林左旗| 玉树县| 辽中县| 石屏县| 常山县| 白河县| 科尔| 离岛区| 来宾市| 雷波县| 三穗县| 张家界市| 牟定县| 民权县| 武城县| 滕州市| 方正县| 太原市| 龙海市| 双鸭山市| 浮山县| 墨竹工卡县| 郓城县|